 HPI-3000 - Jumper Settings 
Jumper Settings for Page Layout, Printer Type & Form Feed Suppression:
Narrow carriage dot matrix (Epson protocol)
Wide carriage dot matrix (Epson protocol)
LaserJet (HP PCL protocol - works with InkJet also)

Optional LaserJet
algorithms:

  • Standard form-feed algorithm
  • Smart form-feed suppression algorithm *
  • Landscape (rotated) text algorith
The 3 jumpers, accessed by removing the cover of the unit, are configured as follows:
Configuration
Left Jumper
Middle Jumper
Right Jumper
Epson - narrow (8")
Open
Open
Open
Epson - wide (13")
Open
Open
Installed
LaserJet
Installed
Open
Open
LaserJet with Form Feed Suppression
Installed
Installed
Open
Landscape LaserJet
Installed
Open
Installed
Landscape LaserJet with Form Feed Suppression
Installed
Installed
Installed

* Smart Form Feed Suppression eliminates the blank page which is ejected by a laser printer between two successive screen prints (the Print Disp button). A blank page may still be ejected at other times, since the HPI-3000 can't detect the buffer status of the laser printer, and passes all other form feed commands from the Universal Station to the printer.